GENERAL SPECIFICATIONS
|
|
Display
|
62 mm x 34 mm supper large LCD
display, 13 mm ( 0.5" ) digit size.
|
Sampling Time
|
Approx. 0.4 second.
|
|
Hold Function
|
To freeze the display reading value.
|
|
Probe type
|
5 types :
1. Platinum PT 100 ohm
( 0.00385 alpha coefficient, meet DIN IEC 751 )
2. Thermocouple type K.
3. Thermocouple type J.
4. Thermocouple type T.
5. Thermocouple type E.
6. Thermocouple type R.
|
Memory Recall
|
Memorize the Maximum, Minimum
reading with recall.
|
|
Over Indication
|
Show " - - - - ".
|
|
Data Output
|
RS232 PC serial interface.
|
|
Power Supply
|
Heavy duty or Akaline type,
DC 9V battery, 006P, MN1604 ( PP3 )
or equivalent.
|
|
Power
Consumption
|
Approx. DC 15 mA.
|
|
Functions
|
℃, ℉, 0.010.1 Data hold, relative measurement.
|
Operating
Temperature
|
0 to 50 ℃ (32 to 122 ℉).
|
|
Resolution
|
0.01℃/0.1℃, 0.01℉/0.1℉.
|
Operating
Humidity
|
Less than 80% RH.
|
|
Circuit
|
Use the software to make linearity
correction instead the traditional hardware circuit.
|
|
Meter Size
|
HWD 180x72x32 mm ( 7.1x2.8x1.3 inch
|
|
Meter Weight
|
285 g/0.62 LB.
|
|
Probe input
socket
|
Pt 100 ohm probe :
DIN 4 pin socket.
Thermocouple couple probe :
Standard 2 pin type K socket.
|
Standard
Accessory
|
Operational manual..... 1 PC.
|
|
Optional
Accessories
|
Carrying case, Pt-100 probe,
Type K Thermocouple probe.
|
|
MEASURING RESOLUTION / RESOLUTION
|
|
Type
|
Resolution
|
Range
|
Type
|
Resolution
|
Range
|
|
Platinum
PT 100 ohm
|
0.01 ℃
|
-199.99 to 199.99 ℃
|
Thermocouple
type T
|
0.01 ℃
|
-100.00 to 100.00 ℃
|
|
0.1 ℃
|
200.0 to 850.0 ℃
|
0.1 ℃
|
100.0 to 400.0 ℃
|
|
0.02 ℉
|
-199.99 to 392.00 ℉
|
0.02 ℉
|
-148.00 to 212.00 ℉
|
|
0.2 ℉
|
392.0 to 1562.0 ℉
|
0.2 ℉
|
212.0 to 752.0 ℉
|
|
Thermocouple
type K
|
0.01 ℃
|
-100.00 to 100.00 ℃
|
Thermocouple
type E
|
0.01 ℃
|
-80.00 to 90.00 ℃
|
|
0.1 ℃
|
100.0 to 1370.0 ℃
|
0.1 ℃
|
90.0 to 779.9 ℃
|
|
0.02 ℉
|
-148.00 to 212.00 ℉
|
0.02 ℉
|
-112.00 to 194.00 ℉
|
|
0.2 ℉
|
212.0 to 2498.0 ℉
|
0.2 ℉
|
194.0 to 1435.8 ℉
|
|
Thermocouple
type J
|
0.01 ℃
|
-90.00 to 100.00 ℃
|
Thermocouple
type R
|
0.1 ℃
|
0 to 600.0 ℃
|
|
0.1 ℃
|
100.0 to 900.0 ℃
|
1 ℃
|
600 to 1770 ℃
|
|
0.02 ℉
|
-130.00 to 212.00 ℉
|
0.2 ℉
|
32.0 to 112.0 ℉
|
|
0.2 ℉
|
212.0 to 1652.0 ℉
|
1 ℉
|
112 to 3218 ℉
|
|
OPTIONAL TEMPERATURE PROBE & OTHER ACCESSORIES
|
|
Carrying Case
|
Model : CA-03, Vinyl soft carrying case.
|
|
Carrying Case
|
Model : CA-06, Hard carrying case
|
|
PT-100 ohm Probe
TP-100
TP-100A
|
* -50 ℃ to 400 ℃ (-58 ℉ to 752 ℉), DIN plug, 4 pins/4 wires, Class A, Cooperate with an
0.00385 alpha coefficient, meet DIN IEC 751, Accuracy : (0.15 + (0.002 x T))C.
* Dimension Sensing head - 152 mm tube, Probe length - 245 mm.
|
|
Thermocouple Probe
(Type K) TP-01
|
* Measure Rage: -40 ℃ to 250 ℃, -40 ℉ to 482 ℉.
* Ultra fast response naked-bead thermocouple, general purpose application.
|
|
Thermocouple Probe
(Type K), TP-02A
|
* Measure Range: -50 ℃ to 900 ℃, -50 ℉ to 1650 ℉.
* Dimension: 10 cm tube, 3.2 mm Dia.
|
|
Thermocouple Probe
(Type K), TP-03
|
* Measure Range: -50 ℃ to 1200 ℃, -50 ℉ to 2200 ℉.
* Dimension: 10 cm tube, 8 mm Dia.
|
|
Surface Probe
(Type K), TP-04
|
* Measure Range: -50 ℃ to 400 ℃, -50 ℉ to 752 ℉.
* Size : Temp. sensing head - 15 mm Dia. Probe length - 120 mm.
|
|
RS232 cable
|
Model : UPCB-01, RS232 cable for connecting between the meter & computer COM port
|
|
USB cable
|
Model : USB-01, USB cable for connecting between the meter & the computer USB port.
|
|
Software
|
Model : SW-U801-WIN, Windows version.
* Software apply as the performance of data logging system & data recorder...
|
|